Highlights- 3 In 1 Function: This product ingeniously integrates digital oscilloscope, multimeter and signal generator functions into one machine.
- Digital Oscilloscope Function: Dual channel oscilloscope function, with the real-time sampling rate of 200Msps and bandwidth of 80MHz. With complete trigger function (automatic, single, regular)
- Multimeter Function: 6000 count auto ranges Ture RMS. Relative value measurement, effectively eliminating wire resistance, distributed capacitance or interference signals.
- Signal Generator Function: 3 kinds of signal waveforms of sinewave, squarewave, trianglewave can be measured. Frequency and amplitude can be set independently.
- Compact Size & Reliable Quality: Lightweight and portable, also can be used as a portable tool for on-site debugging. Adopts ABS anti-drop housing, anti-slip concave design, high elasticity keys, simple interface, easy operation.
OverviewSpecifications:
Name: 3in1 Digital Oscilloscope
Material: ABS
Display: 320*240, 2.8 inches TFT color screen
Battery: 2 * built-in 2000mah rechargeable lithium battery
(included)
Backlight: brightness adjustable; backlight time 30s-120s adjustable or off
Automatic shutoff time: 15-60min or off
Charging voltage: 5VDC, 3A
Usage environment: 0°C to 40°C; <75%RH
Storage condition: -10°C to +60°C; <90%RH
Item size: 100 * 210 * 40mm / 3.94 * 8.27 * 1.57in
Item weight: 480g / 1.06lb
Package size: 237 * 185 * 55mm / 9.33 * 7.28 * 2.17in
Package weight: 830g / 1.83lb
Oscilloscope:
Real-time sample rate: 200Msps
Analog Bandwidth: 80MHz
Input resistance: 1ΜΩ
Vertical resolution: 8 bits
Nonlinearity: ±1 bit
Channel quantity: 2
Input impedance: Approx. 1ΜΩ
Indexing: Vertical 4.0, Horizontal 6.0
Vertical sensitivity ranges: Input BNC at 10mV/div~10V/div
Time base ranges: 5ns/div ~50s/div, 1-2-5 steps
Verticalwave amplitude accuracy: ±(5%+ 0.2div)
Time base accuracy: ±(0.01%+ 0.1div)
Scan mode: Auto, Normal, Single
Trigger Level: ± 4 div (0.04 div per step)
Trigger slope selection: Rising, Falling, Double
Trigger position adjustment: ± 4 div (0.04 div per step)
Automatic settings: Automatic setting of time base and vertical amplitude
Cursor measurement function: ▽V, △T
Optional bandwidth limitation: 20MHz, typical
Voltage measurement parameters: Vp-p, Vp, Vmax, Vmin, Vavg, Vrms
Time measurement parameters: Freq, Period, +Width, -Width, +Duty, Duty
Automatic measurement accuracy: ±(5%+ 0.2div)
Record length: 6K maximum for single channel, 3K per channel for dual channel
Signal Source:
Waveform frequency:
Sinewave: 1Hz-5MHz
Squarewave: 10Hz-1MHz
Trianglewave: 10Hz-1MHz
Waveform amplitude: 5Vpp, 3Vpp, 2Vpp, 1Vpp, 500mVpp, 200mVpp, 100mVpp, OVpp
Multimeter:
DCvoltage: 600.0mV, 0.1mV; 6.000V, 1mV; 60.00V, 10mV; 600.0V, 100mV; 1000V, 1V (0.75.0%rdg +10dgt)
AC Voltage: 600.0mV, 0.1mV; 6.000V, 1mV; 60.00V, 10mV; 600.0V, 100mV; 750V, 1V
50Hz~400Hz(1%rdg +10dgt) 400Hz~1kHz (above 1kHz for reference only)(1.2%rdg +10dgt)
DCCurrent: 60.00/500.0mA, 10μΑ /100μΑ; 6.000/10.00A, 1mA/10mA(1.2%rdg +10dgt)
AC Current True RMS: 60.00/500.0mA, 10μΑ /100μΑ; 6.000/10.00A, 1mA/10mA(1.5%rdg +10dgt)50Hz~1kHz (above 1kHz for reference only)
Resistance: 600.0Ω, 0.1Ω; 6.000kΩ, 1Ω; 60.00kΩ, 10Ω; 600.0kΩ, 100Ω; 6.000ΜΩ, 1k(1.0%rdg+5dgt); 60.00ΜΩ, 10k(3.0%rdg + 5dgt)
Capacitance: 9.999nF, 1pF; 99.99nF, 10pF; 999.9nF, 100pF (2.0%rdg + 10dgt); 9.999μF, 1nF; 99.99uF, 10nF; 999.9uF, 100nF (3.0%rdg +10dgt) ; 9.999mF, 1μF; 99.99mF, 10μF (10.0%rdg +10dgt)
Frequency: 9.999Hz~9.999MHz, 0.001Hz~1kHz (1.0%rdg+5dgt) signal amplitude not less than1Vр-р
Duty cycle: 0.01~99.99% (AC 500mVp-p)
Diode testing: Open circuit voltage about 3.0 V, maximum test current about 2 mA
On-Off test: Judgment resistance: about 50Ω
Automatic ranges switching: Can be applied to each measurement function
Range overflow indication: "O. L" (Over load)
Multimeter measurement rate: 2.5 times/s
Dynamic data refresh: Dynamic refreshing of actual measurement data continues after the main display is held