OverviewPROTECTION AGAINST HIGH AND LOW VOLTAGE AND CURRENT RETURN FOR HOME AUTOMATICALLY AFTER DIRECT CURRENT SUITABLE FOR CURRENT UP TO 40A LIFETIME 100000 TIMES DISPLAY AND PLUG CAN BE USED WITH THE ORIGINAL FACTORY SETTINGS OR RESET INCLUDED WITH THE DEVICE MANUAL FOR USE AND ADJUSTMENT IN ARABIC Over-current protection 4. Automatic recovery 5.Voltage display (voltage measurement) 6.Current display (current measurement) 7. Voltage calibration: voltage + -10% adjustable. A13 8. Restore factory settings: press the bottom button for more than 12 seconds 9. Error inquiry: press UP button more than 12 seconds Product parameters: 1. Model Number:TOVPD1-60-EC 2. Power Supply:230VAC 50/60Hz 3.Max.Loading power:1~63A adjustable(default:40A) 1~40A adjustable(default:63A) 4.Over voltage protection value range:230V~300V(default:270V)Over voltage recovery voltage range:225V - 295 V(default:250V) Overvoltage protection working time:0.1s~30s (default value:0.5s) Over voltage supply mode delay time:1s to 500s (default:30s) 5.Low voltage protection value range:140V-210V (default:170V ) ) ) Voltage recovery voltage range Low:145V-215V (default:190V) Low voltage protection working time:0.1s to 30s (default:0.5s) Low voltage ecovery delay time:1s~500s (default:30s) 6.Over-current adjustment range:1-40A (default: 20A) 20A) 1-63A (default:40A) Working overcurrent range:0.1~30s (default:0.5s) Overcurrent ecovery delay time:1s~500s (default:30s) 7- Working delay time:1s to 500s (default:10s) 9. Power consumption: <2W 10.Electric machine life:100,000 times
Specifications
Model Number
80A
Added to cart
Cart Total EGP 1550.00
We're Always Here To Help
Reach out to us through any of these support channels
'`noon`', the 'noon device', 'noon east', 'east' and the 'east device' are trade marks or registered trade marks of Noon AD Holdings LTD. in the UAE and other countries